EHV, HT & LT Cables · Lightning Arrestors (ESE) · EV Chargers
Our Products
A practical range of electrical, power and infrastructure products supplied for industrial, commercial and project requirements.
Our product range covers essential electrical and infrastructure requirements, helping customers source multiple products for industrial, commercial and infrastructure projects.
Our Primary Product Line
Industrial battery charging solutions designed for reliable DC backup power, demanding industrial environments and mission-critical applications.
Endurance Series
Analog-controlled thyristor charger built to withstand surges, heat and dust, with potentiometer-based voltage and current tuning for predictable operation in substations and remote industrial sites.
Up to 360 V · 5A–3000A · 6/12/24-pulse thyristor
Agile Alpha Series
Engineered for environments where real-time insight, automation and precision control are essential — optimising performance and providing complete visibility through advanced monitoring and diagnostics.
±1% regulation · 25+ parameters · 7-inch touchscreen
Optima Series
Cutting-edge modular technology delivering exceptional efficiency, seamless expandability and intelligent system management, with hot-swappable modules and a compact footprint for mission-critical environments.
>90% efficiency · PF >0.90 · hot-swappable modules
Vector Series
Next-generation IGBT technology delivering superior efficiency, rapid response to load variations and stable output under dynamic grid and system conditions, with DSP-controlled regulation and robust protection.
>90% efficiency · near-unity PF · 5A–3000A
Endurance Series
Analog-controlled thyristor charger built to withstand surges, heat and dust, with potentiometer-based voltage and current tuning for predictable operation in substations and remote industrial sites.
Agile Alpha Series
Engineered for environments where real-time insight, automation and precision control are essential — optimising performance and providing complete visibility through advanced monitoring and diagnostics.
Optima Series
Cutting-edge modular technology delivering exceptional efficiency, seamless expandability and intelligent system management, with hot-swappable modules and a compact footprint for mission-critical environments.
Vector Series
Next-generation IGBT technology delivering superior efficiency, rapid response to load variations and stable output under dynamic grid and system conditions, with DSP-controlled regulation and robust protection.
Power & Cables
01
Power cables for high voltage, medium voltage and low voltage applications across industrial, commercial and infrastructure projects.
Protection
02
Early Streamer Emission lightning protection systems for buildings, industrial facilities and infrastructure applications.
EV Infrastructure
03
EV charging equipment for residential, commercial and public charging applications.
Power & Cables
04
Industrial battery chargers and DC power systems for reliable backup and critical power applications.
Cable Accessories
05
Cable connection and termination accessories for electrical installations and industrial applications.
Battery Monitoring
06
Continuous monitoring and diagnostics for battery banks, helping identify battery condition, performance and potential issues in critical DC power systems.
Power, control and instrumentation cables across extra-high, high and low voltage grades, supplied to the conductor, insulation, armouring and sheathing configuration a project specifies.
Extra-high-voltage power cables for transmission, substations and heavy industrial electrical infrastructure.
Single-core copper or aluminium conductor with semi-conducting conductor screen, XLPE insulation and extruded semi-conducting insulation screen, copper screen with semi-conducting water-blocking tape, and extruded high-density polyethylene outer sheath. Poly-aluminium laminated, extruded metallic lead or corrugated aluminium sheath available as required.
Standards: IS 7098-3 · IEC 60840 · IEC 62067 · ICEA S-108-720
High-voltage / medium-voltage power cables for industrial plants, substations, infrastructure and distribution networks.
Single-core and three-core copper or aluminium conductor, XLPE or EPR insulated, insulation screened with copper wire, copper tape or plain WS tape, unarmoured or GI steel (aluminium for single core) flat/round armoured, with PE / PVC ST2 / FR / FRLS / LSZH sheathing. Lead sheath available where required.
Range: 35 sq. mm to 1200 sq. mm
Standards: IS 7098-II 2016 · IEC 60502-2 · BS 6622 / BS 7835 / BS 5467 · ICEA S-93-639
Stranded compacted aluminium conductor, conductor screened by semi-conducting compound, XLPE insulated, insulation screened by semi-conducting compound and copper tape, PVC sheathed, with messenger conductor supplied with or without insulation as required.
Standards: IS 14255
Low-voltage power, control and instrumentation cables for industrial, commercial and electrical installation applications.
1100 volts grade copper or aluminium power cables with solid or stranded conductor, PVC or XLPE insulated, cores laid up with PVC / FR / FRLS / LSZH inner sheath, unarmoured or armoured, and extruded PVC / FR / ST2 / FRLS / LSZH outer sheath. Lead sheath available where required.
Range: 1.5 sq. mm to 1000 sq. mm · 1 / 2 / 3 / 3.5 / 4 core
Standards: IS 1554-1 · IS 7098 (Part 1) 1988 · BS 5467 / BS 6724 · IEC 60502-1
1100 volts grade control copper cables with solid or stranded conductor, PVC or XLPE insulated, cores laid up with PVC ST2 / FR / FRLS / LSZH extruded inner sheath, unarmoured or armoured with strip or round wire. Metallic screened control cable available on demand.
Range: 2 to 100 core in 1.5 and 2.5 sq. mm
Standards: IS 1554 · IS 7098 (Part 1) 1988 · IEC 60502-1 · BS 5467 / BS 6724 / BS EN 50288
XLPE or black HDPE insulated aluminium conductors laid together around an aluminium alloy / ACSR insulated or bare messenger wire to form the aerial bunched cable. Optional neutral and street lighting conductor.
Solid, stranded or flexible copper conductor, PE / XLPE / PVC / XLPO / EPR / silicone rubber insulated, in pair, triad or quad formation, individually or overall aluminium-mylar screened with drain wire, copper wire braid or copper tape, unarmoured or GI armoured. Lead alloy or polyamide metallic barrier sheath available where required.
Standards: IS 1554 · IS 7098 Pt-1 · BS EN 50288-7
3+3(E) or 4-core flexible copper conductor insulated with XLPE, PE or PP, cores laid up, aluminium-mylar with tinned copper wire braid, PVC sheathed — for variable frequency drive applications.
Standards: IS 7098-1 · IEC 60502-1
Solid JX / KX thermocouple alloy conductors, XLPE or PVC insulated, individually or overall aluminium-mylar taped with drain wire shielding, inner sheathed, armoured or unarmoured, with flame and sunlight resistant PVC outer sheath.
Standards: EN 50288-7
Early Streamer Emission lightning protection for buildings, industrial facilities, solar installations and infrastructure projects.
Early Streamer Emission air terminals for structural lightning protection, installed with a dedicated down conductor and earthing arrangement. Suitable for buildings, industrial facilities, solar installations and infrastructure projects. ESE technical reference →
Chhabi EVSE charging equipment for residential, commercial and public charging applications, covering both DC fast charging and AC slow charging.
Direct-current fast chargers that bypass the vehicle on-board converter, enabling charging in under an hour. Used for public charging stations, public transport and fleet charging. Available in single-gun and dual-gun options with CCS-2, CHAdeMO and GB/T connector options, OCPP 1.6J connectivity over WiFi, Ethernet, 4G SIM or RFID, 7-inch or 10-inch LCD touch screen, and optional support for capacity expansion.
Range: 30 / 60 / 120 / 180 / 240 kW
Standards: Ingress protection IP54, customisable to IP55
Alternating-current chargers that supply grid power through the vehicle on-board converter, suited to overnight home charging, commercial parking and fleet charging. Available in single-gun and dual-gun options with Type-1 and Type-2 connector options, interactive display, load balancing across multiple chargers, and ground or wall mounting.
Range: 7.4 / 22 kW
Standards: Ingress protection IP65 · OCPP 1.6J
Industrial battery chargers and DC power systems for reliable backup and critical power applications across plant and substation environments.
DC power and battery charging equipment for industrial, plant and substation applications where a reliable backup supply is required. Configurations are specified against the battery type, capacity and duty of each installation.
Cable termination and connection accessories — lugs, terminals, connectors, cable glands and crimping tools for electrical installations and industrial applications.
Copper tube terminals in medium duty, heavy duty long barrel, extended palm and reducer forms, plus copper tubular long barrel terminals, DIN type terminals, ICF series terminals, and heavy duty, insulated and light duty in-line connectors.
Standards: BS 4579 / IEC 61238
Aluminium tube terminals in standard and long barrel forms, two-hole and reducer terminals, aluminium in-line connectors, and terminals and connectors for aluminium XLPE insulated conductors.
Friction-welded bi-metallic connectors and terminals, and aluminium alloy tubular bi-metallic terminals, for aluminium-to-copper transitions.
Copper and aluminium sector lugs in long and short barrel forms, with copper and aluminium connectors, for 2C, 3C, 3.5C and 4C sector shaped conductors.
Ring, pin and fork terminals in non-insulated, insulated and double-grip pre-insulated forms, together with snap-on terminals, end sealing ferrules and copper twin type lugs.
Double compression armoured weather and flame proof brass cable glands, medium duty armoured, un-armoured, single compression and SIBG types, plus brass and nylon PG glands and flange type cable glands.
Double compression armoured weather and flame proof SS316 / SS304 cable glands with NPT or metric threading, supplied with earth tags and LSF / LSZH shrouds.
Hydraulic and mechanical hand-operated crimping tools, self-adjustable crimping pliers, hexagonal crimping tools, hydraulic pumps, cable cutters, cutter and stripper tools, modular crimping tools, heat gun and corrosion inhibiting compound.
Continuous monitoring and diagnostics for battery banks, measuring cell and string parameters in real time to identify battery condition, performance and developing faults in critical DC power systems. Compatible with VRLA, VLA and Ni-Cd batteries.
Measures the voltage, internal resistance and temperature of each battery and transmits the readings to the control unit over Modbus. Battery modules are addressed automatically, and batteries with manufacturing failures are detected immediately.
Standards: VRLA / VLA / Ni-Cd compatible
Measures string current, ambient temperature and humidity and transmits the readings to the Control Module over Modbus, using an integrated current sensor.
Range: Up to 480 batteries across 4 strings
Sits at the centre of the system, saving and processing the parameters sent by the battery and string modules. The embedded server provides easy commissioning and hosts the monitoring software, with multiple sites viewable on a single screen and multiple users at different authorisation levels.
Standards: MODBUS TCP/IP · MODBUS RTU · SNMP · Dry Contacts · Ethernet